Type | XNSA48 -1KD |
XNSA48 -2KD |
XNSA110 -3KD |
XNSA220 -5KD |
XNSA220 -10KD |
XNSA48 -5KD |
XNSA220 -10KD |
XNSA220 -30KD |
|||
DC input |
Input rated voltage | 48 Vdc | 110 Vdc | 220 Vdc | 48AVdc | 220Vdc | |||||
Input rated current | 25.4A | 50.8A | 30.3 A | 25.2 A | 50.5 A | 127A | 50.5 A | 153A | |||
AC output |
Output rated capacity(KVA) | 1.0 | 2.0 | 3.0 | 5.0 | 10 | 5.0 | 10.0 | 30.0 | ||
Output rated power | 0.8 kW | 1.6 kW | 2.4 kW | 4.0 kW | 8.0 kW | 4.0kW | 8.0kW | 24 kW | |||
Output rated voltage and frequency | 220 Vac,50Hz | ||||||||||
Output rated current | 4.5 A | 9.0A | 13.6 A | 22.7 A | 45 A | 7.6 A | 15.2 A | 45.3 A | |||
Output voltage accuracy | AC220 V± 3% | ||||||||||
Output frequency accuracy | 60 Hz±0.05 | ||||||||||
Waveform distortion | ≤3% | ||||||||||
Dynamic response(load 0↔100%) | 5% | ||||||||||
Power factor | 0.8 | ||||||||||
Overload | 150%,10s | ||||||||||
Crest factor | 3:1 | ||||||||||
Inverter efficiency | 82% | 90% | 82% | 90% | |||||||
Dielectric strength(input and output) | 1500 VAC,1minute | ||||||||||
Noise(1meter) | ≤50dB | ||||||||||
Temperature | -25ºC~+55ºC | ||||||||||
Humidity | 0-95%,No condensation | ||||||||||
Altitude(m) | ≤5000meters(when over 1000 meters according to GB/T3859.2 reduce the using amount) | ||||||||||
W*D*H(mm) | 482*405* 133 |
482*420*223 | 600*400* 700 |
500*500* 860 |
580*520* 1200 |
650*580*1500 | |||||
Protection | Input reverse connection protection, input under voltage protection, input over-voltage protection, output overload protection, output short circuit protection, overheat protection |
Model | XNSA220-50KS | XNSA220- 100KS | XNSA480- 200KS | XNSA480- 300KS | XNSA480- 500KS | XNSA480- 800KS | XNSA480- 1000KS | |
DC input | Input rating voltage(Vdc) | 480 | ||||||
Input rating current(A) | 127 | 253 | 462 | 694 | 1157 | 1851 | 2314 | |
Input DC voltage allowing range(Vdc) | 420~800 | |||||||
AC output | Output rating capacity(KVA) | 50 | 100 | 200 | 300 | 500 | 800 | 1000 |
Output rating voltage and frequency | AC380V/220 Vac, 50Hz(Three-phase four-wire) | |||||||
Output rating current(A) | 75.6 | 151.5 | 303.9 | 455.8 | 759.7 | 1215.5 | 1519.4 | |
Output voltage precision(V) | AC380V±3% | |||||||
Output frequency precision(Hz) | 50/60hz±0.05 | |||||||
Wave distortion(THD) | ≤3% | |||||||
Dynamic response | 5% | |||||||
Power factor(PF) | 0.8 | |||||||
Overload ability | 150%,10 seconds | |||||||
Crest factor(CF) | 3:1 | |||||||
Inverted efficiency | 92% | |||||||
Insulation strength | 1500 Vac,1minute | |||||||
Noise (1meter) | ≤55dB | |||||||
Using condition temperature | -25ºC~+55ºC | |||||||
Humidity | 0-95%,non-condensing | |||||||
Altitude (m) | ≤6000 | |||||||
Dimension(W*D*H)mm | 800*600*2260 | 1000*800*2060 | 2000*800*2060 | 5400*600*2260 | ||||
Weight (Kg) | 600 | 1100 | 1500 | 1600 | 2000 | 3000 | 4500 | |
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection |
No. | item | |
1 | General test items | DC resistance of stator winding of drive motor |
Overspeed test | ||
Operating voltage range | ||
2 | Torque -speed -efficiency curve | Torque - Speed curve (universal curve) |
Motor controller speed - Efficiency universal curve | ||
Drive motor efficiency | ||
Drive motor system efficiency | ||
3 | Measurement of key characteristic parameters | Continuous torque |
Continuous power | ||
Peak torque | ||
peak power | ||
Maximum operating speed | ||
Efficient workspace | ||
Maximum efficiency | ||
4 | control accuracy | Speed control accuracy test |
Torque control accuracy test | ||
5 | Response | Speed response time |
Torque response time | ||
6 | Operating current of drive motor controller | Continuous operating current |
Short time operating current | ||
Max operating current | ||
7 | Continuous feed characteristics | |
8 | Controller protection function test | |
9 | Reliability test(GB/T 29307-2012) | |
10 | Short time voltage rise test | |
11 | Locked rotor torque and locked rotor current test | |
12 | Motor temperature rise test | |
13 | Load test | |
14 | Energy feedback test | |
15 | Road simulation test (climbing, acceleration, rolling resistance, etc.) | |
16 | Contact current test | |
17 | Simulation test of ramp starting, uphill and downhill taxiing | |
18 | Steady state cyclic loading durability test | |
19 | Other simulation tests (such as acceleration, braking, parking, etc.) or custom working conditions |
Model | XD40-800/24-100-1 | XD80-800/24-300-1 | XD120-800/24-500-1 | XD150-800/24-500-1 | XD250-800/24-667-1 | XD300-800/24-667-1 | |||||
Rated power | 40kW | 80kW | 120kW | 150kW | 250kW | 300kW | |||||
Peak power | 60kW | 120kW | 156kW | 180kW | 300kW | 360kW | |||||
Rated current | 100A | 300A | 500A | 500A | 667A | 667A | |||||
Peak current | 150A | 450A | 650A | 600A | 780A | 780A | |||||
Rated voltage | 400V | 267V | 240V | 300V | 375V | 450V | |||||
AC characteristics | |||||||||||
Input mode | 3P4W+PE | ||||||||||
Voltage | 380V±15% | ||||||||||
Frequency converter | 50Hz±5Hz | ||||||||||
Power factor | ≥0.99 | ||||||||||
THD | ≤4% | ||||||||||
DC characteristics | |||||||||||
Voltage range | 24V-800V | ||||||||||
Current range | 0-667A | ||||||||||
Voltage ripple | ≤0.2%F.S | ||||||||||
Voltage accuracy | ≤0.1%F.S | ||||||||||
Current accuracy | ≤0.2%F.S | ||||||||||
Feedback characteristics | |||||||||||
AC voltage | 323V~437V(Allowed voltage range) | ||||||||||
AC frequency | 45Hz~55Hz(Allowed frequency range) | ||||||||||
Power factor | ≥0.99 | ||||||||||
Feedback power | Support full scale power feedback | ||||||||||
Total harmonic content | ≤4% | ||||||||||
Communication and interface | |||||||||||
Local operation | touch screen | ||||||||||
Remote communication | Can (optional), RS485 (optional), Ethernet (standard) | ||||||||||
External interface | Support emergency stop, start / stop, fault detection, operation status detection, etc | ||||||||||
Safety and environment | |||||||||||
insulation resistance | ≥20MΩ | ||||||||||
Grounding resistance | ≤100mΩ | ||||||||||
Withstand voltage performance | 2000Vdc | ||||||||||
Protection function | Phase loss, overheating, overvoltage, voltage limiting, overcurrent, short circuit and overload | ||||||||||
Degree of protection | IP21 | ||||||||||
Ambient temperature | -20ºC~45ºC | ||||||||||
Ambient humidity | 10%~90%( No condensation) | ||||||||||
Altitude | ≤2000m | ||||||||||
Cooling mode | Forced fan | ||||||||||
Noise | ≤68dB | ||||||||||
Dimensions (W * D * H)mm | 615*650*1680 | 1000*1000*1960 | 1200*1000*1900 | 1200*1000*1900 | 1800*1000*1960 | 1800*1000*1960 |
4.1.Bi-directional DC power supply operation mode
The equipment has five operation modes: constant voltage, constant voltage current limiting, constant current, constant power and constant resistance. The operation parameters of voltage, current and power can be set, and the power protection parameters can be set at the same time
4.2. Control mode selection function
The equipment can set the control mode of the equipment through the operation interface, including local control, communication control, external analog control and default control mode
(1) Local control function
Through the touch screen, control operations such as power operation parameters, operation, stop and fault reset of control equipment can be set. It can also view various parameters of equipment operation and other operation records.
(2) Communication control function
The power operation parameters can be set through the communication software or communication command to control the equipment operation stop, fault reset and other control operations, and the equipment operation parameters and operation records can also be viewed through the touch screen.
(3) External analog control
Control the operation / stop, fault reset, voltage and current regulation of the equipment through the external analog interface, and monitor the power supply voltage, current, operation status and fault status.
(4) Default control
In this control mode, the power supply equipment can be operated through panel operation, communication control and external analog control.
4.3. Emergency stop function
The power supply equipment has emergency stop function. In case of emergency, it can stop the power output through the emergency stop button, communication interface and external control interface on the operation panel.
4.4. Protective device
The power supply equipment has input protection, output overcurrent protection, output overvoltage protection, power device overtemperature protection, IGBT overcurrent protection and programmable OCP, OVP and opp.
4.5. Self discharge function
The power supply output terminal has self discharge function. After the power supply stops output, the power supply can reduce the voltage at the output terminal below the safe voltage within 30s.
Normal operation.
Jinan Xinyuhua Energy Technology Co., Ltd. Firmly grasps the direction of "low-carbon economy and green development", takes "building a first-class new energy enterprise in China and even in the world" as its strategic goal, carries forward the enterprise spirit of "harmony, innovation and pursuit of excellence", strives to contribute clean energy, improve the power structure and fulfill social responsibility. A multi field, large-scale and powerful new energy leading enterprise constantly shows its unique charm and elegant demeanor. It will continue to serve the country with industry, repay the society with value, base on the market with reputation, and gallop into the future with strength, and advance hand in hand with all walks of life to create brilliance together! |
Why Choose US?
• Professional team for after-sale service 7*24
• Experienced R & D team and profesional sales team
• OEM & ODM service, we will evaluate, design and produce your customized products
• Offer confidentiality agreement to protect your profit, with us your business will be in safe your money in safe.