Customization: | Available |
---|---|
Warranty: | 1year |
Nature of Source Flow: | Active Inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | XNSA48 -1KD |
XNSA48 -2KD |
XNSA110 -3KD |
XNSA220 -5KD |
XNSA220 -10KD |
XNSA48 -5KD |
XNSA220 -10KD |
XNSA220 -30KD |
|||
DC input |
Input rated voltage | 48 Vdc | 110 Vdc | 220 Vdc | 48AVdc | 220Vdc | |||||
Input rated current | 25.4A | 50.8A | 30.3 A | 25.2 A | 50.5 A | 127A | 50.5 A | 153A | |||
AC output |
Output rated capacity(KVA) | 1.0 | 2.0 | 3.0 | 5.0 | 10 | 5.0 | 10.0 | 30.0 | ||
Output rated power | 0.8 kW | 1.6 kW | 2.4 kW | 4.0 kW | 8.0 kW | 4.0kW | 8.0kW | 24 kW | |||
Output rated voltage and frequency | 220 Vac,50Hz | ||||||||||
Output rated current | 4.5 A | 9.0A | 13.6 A | 22.7 A | 45 A | 7.6 A | 15.2 A | 45.3 A | |||
Output voltage accuracy | AC220 V± 3% | ||||||||||
Output frequency accuracy | 60 Hz±0.05 | ||||||||||
Waveform distortion | ≤3% | ||||||||||
Dynamic response(load 0↔100%) | 5% | ||||||||||
Power factor | 0.8 | ||||||||||
Overload | 150%,10s | ||||||||||
Crest factor | 3:1 | ||||||||||
Inverter efficiency | 82% | 90% | 82% | 90% | |||||||
Dielectric strength(input and output) | 1500 VAC,1minute | ||||||||||
Noise(1meter) | ≤50dB | ||||||||||
Temperature | -25ºC~+55ºC | ||||||||||
Humidity | 0-95%,No condensation | ||||||||||
Altitude(m) | ≤5000meters(when over 1000 meters according to GB/T3859.2 reduce the using amount) | ||||||||||
W*D*H(mm) | 482*405* 133 |
482*420*223 | 600*400* 700 |
500*500* 860 |
580*520* 1200 |
650*580*1500 | |||||
Protection | Input reverse connection protection, input under voltage protection, input over-voltage protection, output overload protection, output short circuit protection, overheat protection |
Model | XNSA220-50KS | XNSA220- 100KS | XNSA480- 200KS | XNSA480- 300KS | XNSA480- 500KS | XNSA480- 800KS | XNSA480- 1000KS | |
DC input | Input rating voltage(Vdc) | 480 | ||||||
Input rating current(A) | 127 | 253 | 462 | 694 | 1157 | 1851 | 2314 | |
Input DC voltage allowing range(Vdc) | 420~800 | |||||||
AC output | Output rating capacity(KVA) | 50 | 100 | 200 | 300 | 500 | 800 | 1000 |
Output rating voltage and frequency | AC380V/220 Vac, 50Hz(Three-phase four-wire) | |||||||
Output rating current(A) | 75.6 | 151.5 | 303.9 | 455.8 | 759.7 | 1215.5 | 1519.4 | |
Output voltage precision(V) | AC380V±3% | |||||||
Output frequency precision(Hz) | 50/60hz±0.05 | |||||||
Wave distortion(THD) | ≤3% | |||||||
Dynamic response | 5% | |||||||
Power factor(PF) | 0.8 | |||||||
Overload ability | 150%,10 seconds | |||||||
Crest factor(CF) | 3:1 | |||||||
Inverted efficiency | 92% | |||||||
Insulation strength | 1500 Vac,1minute | |||||||
Noise (1meter) | ≤55dB | |||||||
Using condition temperature | -25ºC~+55ºC | |||||||
Humidity | 0-95%,non-condensing | |||||||
Altitude (m) | ≤6000 | |||||||
Dimension(W*D*H)mm | 800*600*2260 | 1000*800*2060 | 2000*800*2060 | 5400*600*2260 | ||||
Weight (Kg) | 600 | 1100 | 1500 | 1600 | 2000 | 3000 | 4500 | |
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection |