Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Output Power: | >1000W |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Mode | XYH-3000T | XYH-5000T | XYH-6000T | XYH-8000T | XYH-10000T | XYH-15000T | XYH-20000T |
Rated power | 3kw | 5kw | 6kw | 8kw | 10kw | 15kw | 20kw |
Max. discharge current | 81.7A | 136A | 163A | 109A | 136A | 163A | 136A |
Input Battery Voltage | 48V | 48V | 48V | 96V | 96V | 120V | 192V |
Input grid AC voltage | 380/400/415Vac 50/60hz | ||||||
Output AC voltage | Three-phase 380/400/415Vac | ||||||
Output current | 4.5A*3 | 7.6A*3 | 9A*3 | 12A*3 | 15A*3 | 23A*3 | 30A*3 |
Output frequency | 50/60hz | ||||||
Size(W*L*H)mm | 350*600*650 | 350*600*650 | 350*600*650 | 400*700*740 | 400*700*740 | 400*700*740 | 400*700*850 |
Weight(Kg) | 73 | 83 | 90 | 100 | 125 | 143 | 150 |
General data | |||||||
Conversion time | 20ms~1s | ||||||
Nominal voltage | ±1%(Steady state load),±3%(Load fluctuation) | ||||||
Output waveform | Pure sine wave | ||||||
Current peak ratio | 3:1 MAX | ||||||
THD | Linear load < 3%; nonlinear load < 5% | ||||||
Standby power | <20W | ||||||
Overload capacity | >120%10s; >150%:5ms | ||||||
Protective function | <±5% | ||||||
Inversion efficiency | >90% | ||||||
Balance load voltage | <±1%;<±5%(Unbalanced load voltage) | ||||||
Protect function | Undervoltage protection of battery,state grid over voltage and undervoltage,inverter overload.overvoltage,over temperature,short circuit,automatic recovery after over voltage and undervoltage changing to normal. | ||||||
communication interface | RS232,(485,Remote Control,Options) | ||||||
Operating temperature | -10~60ºC | ||||||
Relative humidity (non condensing) | 30%~90% | ||||||
Operating altitude (maximum) |
<1000Meters(every increased 1000Meters decrease power1%,highest5000Meters) | ||||||
cooling method | Forced air cooling | ||||||
Noise | ≤55dB(Depending on load and temperature)Distance to machine1M | ||||||
Easy maintenance | The front / upper / left and right sides can be opened. |
Mode | XYH-30000T | XYH-50000T | XYH-60000T | XYH-80000T | XYH-100000T | XYH-150000T | XYH-200000T |
Rated power | 30kw | 50kw | 60kw | 80kw | 100kw | 150kw | 200kw |
Max. discharge current | 163A | 182A | 206A | 213A | 266A | 399A | 531A |
Input Battery Voltage | 240V | 360V | 384V | 384V | 384V | 384V | 384V |
Input grid AC voltage | 380/400/415Vac 50/60hz | ||||||
Output AC voltage | Three-phase 380/400/415Vac | ||||||
Output current | 45A*3 | 75A*3 | 91A*3 | 121A*3 | 151A*3 | 227A*3 | 303A*3 |
Output frequency | 50/60hz | ||||||
Size(W*L*H)mm | 600*700*1360 | 600*800*1800 | 600*800*1800 | 700*800*1960 | 700*800*1960 | 700*800*2200 | 800*1000*2200 |
Weight(Kg) | 298 | 380 | 390 | 470 | 578 | 700 | 1400 |
General data | |||||||
Conversion time | 20ms~1s | ||||||
Nominal voltage | ±1%(Steady state load),±3%(Load fluctuation) | ||||||
Output waveform | Pure sine wave | ||||||
Current peak ratio | 3:1 MAX | ||||||
THD | Linear load < 3%; nonlinear load < 5% | ||||||
Standby power | <20W | ||||||
Overload capacity | >120%10s; >150%:5ms | ||||||
Protective function | <±5% | ||||||
Inversion efficiency | >90% | ||||||
Balance load voltage | <±1%;<±5%(Unbalanced load voltage) | ||||||
Protect function | Undervoltage protection of battery,state grid over voltage and undervoltage,inverter overload.overvoltage,over temperature,short circuit,automatic recovery after over voltage and undervoltage changing to normal. | ||||||
communication interface | RS232,(485,Remote Control,Options) | ||||||
Operating temperature | -10~60ºC | ||||||
Relative humidity (non condensing) | 30%~90% | ||||||
Operating altitude (maximum) |
<1000Meters(every increased 1000Meters decrease power1%,highest5000Meters) | ||||||
cooling method | Forced air cooling | ||||||
Noise | ≤55dB(Depending on load and temperature)Distance to machine1M | ||||||
Easy maintenance | The front / upper / left and right sides can be opened. |
Model | XNSA480- 300KS | XNSA480- 500KS | XNSA480- 800KS | XNSA480- 1000KS | XNSA480- 1500KS | XNSA480- 3000KS | |||||||||||||||
DC input | Input rating voltage(Vdc) | 480 | |||||||||||||||||||
Input rating current(A) | 694 | 1157 | 1851 | 2314 | 3437 | 6875 | |||||||||||||||
Input DC voltage allowing range(Vdc) | 420~800 | ||||||||||||||||||||
AC output | Output rating capacity(KW) | 300 | 500 | 800 | 1000 | 1500 | 3000 | ||||||||||||||
Output rating voltage and frequency | AC380V Vac, 50Hz(Three-phase four-wire) | ||||||||||||||||||||
Output rating current(A) | 455.8 | 759.7 | 1215.5 | 1519.4 | 2279 | 4558 | |||||||||||||||
Output voltage precision(V) | AC380V±3% | ||||||||||||||||||||
Output frequency precision(Hz) | 50hz±0.05 | ||||||||||||||||||||
Wave distortion(THD) | ≤1% | ||||||||||||||||||||
Dynamic response | 3% | ||||||||||||||||||||
Power factor(PF) | 0.8leading-1-0.8lagging, adjustable | ||||||||||||||||||||
Overload ability | 150%,10 seconds | ||||||||||||||||||||
Crest factor(CF) | 3:1 | ||||||||||||||||||||
Inverted efficiency | 95% | ||||||||||||||||||||
Insulation strength | 1500 Vac,1minute | ||||||||||||||||||||
Noise (1meter) | ≤55dB | ||||||||||||||||||||
Using condition temperature | -25ºC~+55ºC | ||||||||||||||||||||
Humidity | 0-95%,non-condensing | ||||||||||||||||||||
Altitude (m) | ≤6000 | ||||||||||||||||||||
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection |
Jinan Xinyuhua Energy Technology Co., Ltd. Firmly grasps the direction of "low-carbon economy and green development", takes "building a first-class new energy enterprise in China and even in the world" as its strategic goal, carries forward the enterprise spirit of "harmony, innovation and pursuit of excellence", strives to contribute clean energy, improve the power structure and fulfill social responsibility. A multi field, large-scale and powerful new energy leading enterprise constantly shows its unique charm and elegant demeanor. It will continue to serve the country with industry, repay the society with value, base on the market with reputation, and gallop into the future with strength, and advance hand in hand with all walks of life to create brilliance together!
Why Choose US?
• Professional team for after-sale service 7*24
• Experienced R & D team and profesional sales team
• OEM & ODM service, we will evaluate, design and produce your customized products
• Offer confidentiality agreement to protect your profit, with us your business will be in safe your money in safe.
1 Q:Are you manufacturer?
We are a professional power supply manufacturer with high reputation in this field.