Model | AC2000-33300 | AC2000-33600 | AC2000-331000 | AC2000-332000 | AC2000-334000 | AC2000-336000 | AC2000-338000 | ||
Capcity | 30kVA | 60kVA | 100kVA | 200kVA | 400kVA | 600kVA | 800kVA | ||
AC input |
Phase | 3P4W+PE | |||||||
Voltage | Phase voltage:220V±10%,line voltage:380V±10% | ||||||||
Frequency | 50/60Hz±3Hz | ||||||||
AC output | Phase | 3P4W | |||||||
Voltage | Phase voltage:10~300.0V | ||||||||
Frequency | 45.0~65.0Hz | ||||||||
Rated voltage(220Vac) | 90A | 136A | 180A | 302A | 607A | 911A | 1215A | ||
Set voltage accuracy | Resolution: 0.1V, accuracy: 0.2% × Read value + 0.2% × Full scale value | ||||||||
Set frequency accuracy | Resolution: 0.1Hz, accuracy: 0.05% | ||||||||
Test voltage accuracy | Resolution: 0.1V, accuracy: 0.2% × Read value + 0.2% × Full scale value | ||||||||
Test frequency accuracy | Resolution: 0.1Hz, accuracy: 0.05% | ||||||||
current | Resolution: 0.1a/1a, accuracy: 0.3% × Display value + 0.3% × Rated output value | ||||||||
Power | Resolution: 0.1kw/0.01kw/0.001kw, accuracy: 0.45% × Read value + 0.45% × Full scale value | ||||||||
Frequency stability | ≤0.1% | ||||||||
Voltage distortion | Line load:THD<2% | ||||||||
Transient recovery time | 20ms | ||||||||
Voltage peak coefficient | 1.41±0.1 | ||||||||
Source voltage effect | ≤1% | ||||||||
Load effect | ≤1% | ||||||||
Overload capacity | 105% < output ≤ 110% turn off the output in 10 minutes; Turn off the output in 5 minutes when 110% < output ≤ 120%; 120% < output ≤ 150% 2 seconds to turn off the output; | ||||||||
Protect | IGBT overheating, IGBT overcurrent, transformer overheating, output overvoltage, output undervoltage, output overcurrent, output overload and output short circuit | ||||||||
Efficiency | >86% | ||||||||
Display mode | LCD | ||||||||
Online adjustment function | The output voltage and frequency can be adjusted on line (45.0 ~ 65.0hz) | ||||||||
Function | 1. Based on the principle of rectifier + inverter, it can realize 100% energy flow in both directions between load and power grid, and has two functions of power supply and load. 2. Single phase or three-phase AC output can be selected. 3. It can simulate low voltage ride through (LVRT) test curve. 4. It can synthesize fundamental wave and each harmonic wave to simulate power quality adaptability test. 5. With step programming mode, each step can set the output voltage, frequency, operation time, etc., can set the cycle operation, and can set the number of cycles. 6. AC output has a variety of programming modes, which can realize the gradual change and jump of output voltage and frequency. The starting voltage, frequency and ending voltage, frequency and time of gradual change can be set 7. Phase setting range: 0-360 degrees; 8. It can control the change rate of voltage and frequency. 9. The output limits of voltage and current can be set |
||||||||
Communication interface | RS485 (standard), RS232 (optional), Ethernet (optional) | ||||||||
Temperature | 0~40ºC | ||||||||
Humidity | 20~90%RH |
The Definition and principle of Power grid simulator
Jinan Xinyuhua Energy Technology Co., Ltd. Firmly grasps the direction of "low-carbon economy and green development", takes "building a first-class new energy enterprise in China and even in the world" as its strategic goal, carries forward the enterprise spirit of "harmony, innovation and pursuit of excellence", strives to contribute clean energy, improve the power structure and fulfill social responsibility. A multi field, large-scale and powerful new energy leading enterprise constantly shows its unique charm and elegant demeanor. It will continue to serve the country with industry, repay the society with value, base on the market with reputation, and gallop into the future with strength, and advance hand in hand with all walks of life to create brilliance together!
Why Choose US?
• Professional team for after-sale service 7*24
• Experienced R & D team and profesional sales team
• OEM & ODM service, we will evaluate, design and produce your customized products
• Offer confidentiality agreement to protect your profit, with us your business will be in safe your money in safe.
1. Q: Does installation Easy ?
A: Very easy, every customer can do it by themselves, we will supply all the components for installation and very details installation manual.
2. Q: Does our wind is enough for a wind generator ?
A: As our wind generator can start running at low wind speed2.5m/s. so your average annual wind speed is more than 5m/s then you can use it .
3. Q: Which model of wind generator is suitable for me?
A: Please contact our sales with following points :
(1) What appliance do you want to running by the system? How many watts are they and their working time .
(2)Your annual wind speed .
(3)What kinds of system do you want ? On-grid or off-grid
4. Q: Can I only buy parts not whole system?
A: Yes, for example you can manufacture tower on local , we can supply you tower drawing.
5. Q: For horizontal axis wind turbines VS vertical axis wind turbines, which kind of efficiency is better.
A: For same model at same wind speed, the output of horizontal axis wind turbines is more efficient than that of vertical axis wind turbines.