Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | XND220 -3020 |
XND220 -3030 |
XND220 -3050 |
XND220 -3100 |
XND220 -3200 |
XND220 -3450 |
XND220 -3600 |
XND220 -31000 |
XND220 -32000 |
|
DC Input | Output rating voltage (VDC) | 220 | ||||||||
Output rating current (A) | 10.1 | 15.2 | 25..3 | 49.4 | 99 | 222 | 296 | 496 | 988 | |
Input DC voltage allowing range(VDC) | 180~300 | |||||||||
AC bypass input | Allowing input voltage range(VAC) | 380±15% | ||||||||
Input rating current(A) | 3.0 | 4.5 | 7.6 | 15.2 | 30.3 | 68.4 | 91.2 | 151..9 | 303.9 | |
Bypass switch time(ms) | ≤4 | |||||||||
AC output | Rating capacity(KVA) | 2.0 | 3.0 | 5.0 | 10 | 20 | 45 | 60 | 100 | 200 |
Output rating power(KW) | 1.6 | 2.4 | 4.0 | 8.0 | 16 | 36 | 48 | 80 | 160 | |
Output rating voltage and frequency(VAC/Hz) | 380VAC/220VAC,50Hz(three phase four wires) | |||||||||
Output rating wire current(A) | 3.0 | 4.6 | 7.6 | 15.2 | 30.1 | 68.4 | 91.2 | 152 | 304 | |
Output voltage precision(V) | 380±3% | |||||||||
Output frequency precision(Hz) | 50±0.05 | |||||||||
waveform deviation factor (THD) (liner load) |
≤3% | |||||||||
Three-phase load unbalance ability | ≤100% | |||||||||
dynamic response (load 0←→100%) |
5% | |||||||||
Power factor(PF) | 0.8 | |||||||||
Load ability | 150%, 10s | |||||||||
crest factor(CF) | 3:1 | |||||||||
Inverted efficiency (80%resistance load) | 91% | 92% | ||||||||
Working envirnment | Insulation strength(input and output) | 2000VAC,1minute | ||||||||
Noise (1meter) | ≤45dB | |||||||||
using condition temperature | -10ºC~+50ºC | |||||||||
temperature | 0~90%,no condensing | |||||||||
Using altitude(m) | ≤2000 | |||||||||
machine dimension | width,depth,height (mm) | 550×480×980 | 550×485×1200 | 800×600×2260(or double screen) | ||||||
reference weight() | 30 | 45 | 60 | 160 | 200 | 450 | 580 | 860 | 1000 | |
Protection function | Input reversing protection,input low-voltage protection,outputover-load protection,output short-circuit protection,over-heat protection |
Model | XND220 -1010 |
XND220 -1020 |
XND220 1030 |
XND220 -1050 |
XND220 -1100 |
XND220 - 1200 |
XND220 -1300 |
XND220 -1500 |
||||
DC input | input rating voltage (VDC) | 220 | ||||||||||
Input rating current (A) | 5.0 | 10 | 15.2 | 25 | 49 | 99 | 148 | 247 | ||||
Input DC voltage allowing range (VDC) | 180~300 | |||||||||||
AC bypass input | Allowing input voltage range(VAC) | 220±15% | ||||||||||
Input rating current (A) | 4.5 | 9.0 | 13.6 | 22.7 | 45 | 91 | 136 | 227 | ||||
Bypass switch time (ms) | ≤4 | |||||||||||
AC output | Rating capacity (KVA) | 1.0 | 2.0 | 3.0 | 5.0 | 10 | 20 | 30 | 50 | |||
Output rating power (KW) | 0.8 | 1.6 | 2.4 | 4.0 | 8.0 | 16 | 24 | 40 | ||||
Output rating voltage and frequency | 220VAC, 50HZ | |||||||||||
Output rating current (A) | 4.5 | 9.0 | 13.6 | 22.7 | 45 | 91 | 136 | 227 | ||||
Output voltage precision(V) | 220±3% | |||||||||||
Output frequency precision(Hz) | 50±0.05 | |||||||||||
Waveform deviation factor (THD)(liner load) | ≤3% | |||||||||||
Dynamic response (load 0←→100%) |
5% | |||||||||||
Power factor(PF) | 0.8 | |||||||||||
Load ability | 150%,10scends | |||||||||||
Crest factor (CF) | 3:1 | |||||||||||
Inverted efficiency | 90% | 92% | ||||||||||
Working environment | Insulation strength(input and output) | 1500VAC,1minute | ||||||||||
Noise(1meter) | ≤50dB | |||||||||||
using condition temperature | -10ºC~+50ºC | |||||||||||
temperature | 0~90%,no condensing | |||||||||||
Using altitude(m) | ≤2000 | |||||||||||
Machin dimension | verticalwidth,depth,height (mm) | 200×420×400 | 225×480×450 | 550×480×980 | 550×485×1200 | 800×600×2260(or double screen) | ||||||
rackmountablewidth,depth,height (mm) | 482×405×133 | 482×405×178 | 482×420×223 | no | ||||||||
reference weight() | 18 | 30 | 40 | 60 | 150 | 260 | 360 | 700 | ||||
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection | |||||||||||
Model | XUD220 -3050 |
XUD220 -3100 |
XUD220 -3150 |
XUD220 -3300 |
XUD220 -3500 |
XUD220 -31000 |
XUD220 -32000 |
|||
DC input | Input rating voltage (VDC ) | 220 | ||||||||
Input rating current (A) | 25.3 | 49.4 | 74 | 148 | 247 | 494 | 988 | |||
Input DC voltage allowing range (VDC ) | 180 ~ 300 | |||||||||
AC input | Rating AC input voltage(VAC ) | 220( single-phase ) | 380 (three phase four wires) | |||||||
AC voltage allowing range( VAC ) | 220 ± 15% | 380 ± 15% | ||||||||
Input AC allowing frequency ( Hz ) | 45 ~ 60 | |||||||||
Power factor (PF) | 0.9 | |||||||||
Bypass input | Allowing input voltage range(VAC ) | 380 ± 15% (three phase four wires) | ||||||||
Input rating current(A) | 7.6 | 15.2 | 22.8 | 45.6 | 76 | 152 | 304 | |||
AC output | Rating capacity (KVA) | 5 | 10 | 15 | 30 | 50 | 100 | 200 | ||
Output rating power (KW) | 4 | 8 | 12 | 24 | 40 | 80 | 160 | |||
Output rating voltage and frequency | 380VAC , 50Hz (three phase four wires) | |||||||||
Output rating current (A) | 7.6 | 15.2 | 22.8 | 45.6 | 76 | 152 | 304 | |||
Output voltage precision (V) | 380 ± 3% | |||||||||
Output frequency precision (Hz) | 50 ± 0.05 | |||||||||
Waveform deviation factor (THD) ( liner load ) |
≤ 5% | |||||||||
Three-phase load unbalance ability | ≤ 100% | |||||||||
Dynamic response ( load 0 ←→ 100%) |
5% | |||||||||
Power factor (PF) | 0.8 | |||||||||
Load ability | 150%,10 seconds | |||||||||
Crest factor (CF) | 3:1 | |||||||||
Inverted efficiency (80% resistance load ) |
92% | |||||||||
Switchtime(ms) | AC DC screen | 0 | ||||||||
inverter bypass | 4 | |||||||||
Working environment | Insulation strength (input and output) | 2000V AC ,1 minute | ||||||||
Noise ( 1 meter) | ≤ 50dB | |||||||||
using condition temperature | -10 ºC ~+ 50 ºC | |||||||||
humidity | 0~90%, no condensing | |||||||||
Using altitude (m) | ≤ 2000 | |||||||||
machine dimension | width,depth,height(mm) | 550×485×1200 | 800×600×2260(or double screen) | 1000×800 × 2260(or double screen) | ||||||
reference weight ( ) | 90 | 200 | 250 | 450 | 620 | 950 | 2300 | |||
Fault dry contact | Inverter abnormal,AC abnormal,battry abnormal,load abnormal,UPS abnormal | |||||||||
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection | |||||||||
Model | XUD220 -1030 |
XUD220 -1050 |
XUD220 -1100 |
XUD220 -1150 |
XUD220 -1200 |
XUD220 -1500 |
XUD220 -1800 |
||||
DC Input | input rating voltage (VDC ) | 220 | |||||||||
Input rating current (A) | 15.2 | 25 | 49 | 74 | 99 | 227 | 364 | ||||
Input DC voltage allowing range (VDC ) | 180 ~ 300 | ||||||||||
AC input | Rating AC input(VAC ) | 220( single-phase ) | 380 (three phase four wires) | ||||||||
AC voltage allowance(VAC ) | 220 ± 15% | 380 ± 15% | |||||||||
Input AC allowing frequency(Hz ) | 45 ~ 60 | ||||||||||
Power factor (PF) | 0.85 | 0.9 | |||||||||
Bypass input | Allowing input voltage rangge(VAC ) | 220 ± 15% | |||||||||
Input rating current (A) | 13.6 | 22.7 | 45 | 68 | 90 | 227 | 364 | ||||
AC output | Rating capacity (KVA) | 3.0 | 5.0 | 10 | 15 | 20 | 50 | 80 | |||
Output rating power (KW) | 2.4 | 4.0 | 8 | 12 | 16 | 40 | 64 | ||||
Output rating voltage and frequency | 220V AC , 50Hz | ||||||||||
Output rating current (A) | 13.6 | 22.7 | 45 | 68 | 91 | 227 | 364 | ||||
Output voltage precision (V) | 220 ± 3% | ||||||||||
Output frequency precision(Hz) | 50 ± 0.05 | ||||||||||
Waveform deviation factor (THD) ( liner load ) |
≤ 3% | ||||||||||
Dynamic response (load 0←→100%) |
5% | ||||||||||
Power factor (PF) | 0.8 | ||||||||||
Load ability | 150%,10 scends | ||||||||||
Crest factor (CF) | 3:1 | ||||||||||
Inverted efficiency (80% resistance load ) |
90% | ||||||||||
Switch time (ms) | AC DC screen | 0 | |||||||||
Inverter bypass | ≤ 4 | ||||||||||
Working environment | Insulation strength (input and output) | 1500V AC ,1 minute | 2000V AC ,1 minute | ||||||||
Noise (1meter) | ≤ 50dB | ||||||||||
using condition temperature | -10 ºC ~+ 50 ºC | ||||||||||
Humidity | 0~90%, no condensing | ||||||||||
Using altitude (m) | ≤ 2000 | ||||||||||
machine dimension | width,depth,height (mm) | 482 × 450× 266 | 550 ×480× 980 | 550×480× 980 800×600× 2260 |
800×600×2260(or double screens) | 1000×800×2260(or double screens) | |||||
reference weight ( ) | 60 | 80 | 360 | 400 | 460 | 1000 | 1600 | ||||
Fault dry contact | Inverter abnormal,AC abnormal,battery abnormal,overload fault,UPS fault | ||||||||||
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection | ||||||||||
Why Choose US?
• Professional team for after-sale service 7*24
• Experienced R & D team and profesional sales team
• OEM & ODM service, we will evaluate, design and produce your customized products
• Offer confidentiality agreement to protect your profit, with us your business will be in safe your money in safe.
Trade Term:
• Payment term:Western Union, T/T
• Leading time:10-30 working days
• Freight cost: Customers's shipping agent or our forwarder
1. Q:Are you manufacturer?
We are a professional power supply manufacturer with high reputation in this field.